HICOS GIS-C
Compact/Extensible gas insulated switchgear with three position switch-disconnector, vacuum circuit breaker, fuses, current and voltage sensors, measurement voltage sensors, for secondary distribution. Outdoor compact version available. Tested at CESI according to IEC Standards. Enel GSM001 - GSCM004 approved. Service continuity LSC2A. Patent pending.
Medium voltage secondary distribution
Up to 36 kV / 630 A / 25 kA
Up to 36 kV / 630 A / 25 kA
Description
HICOS GIS-C compact, made up of gas-insulated enclosure that group up to 5 functional units
Fields of application
Medium voltage secondary distribution networks: renewable energy, utilities, light industry, oil & gas, chemical plants, water treatment, data centers, rail transport, airports, infrastructures, shopping centers, service sectors, etc.
Certifications and approval
- Tested at CESI according to IEC Standards:
- CESI C1014760 Circuit breaker making and breaking test
- CESI C1016331 Circuit breaker making and breaking test and short time withstand and peak withstand tests
- CESI C1018556 Circuit breaker electrical endurance tests
- CESI C1020190 Switch-disconnector making and breaking test and short-circuit making tests
- CESI C1021794 Electromagnetic compatibility
- CESI C2000216 Switch-disconnector short time withstand and peak withstand tests
- CESI C2000308 Earthing-switch of SD short-circuit making tests
- CESI C2000517 Switch-disconnector special test no-load transformer
- CESI C2002953 Arcing due to internal fault
- CESI C2005247 Earthing-switch of CB short-circuit making tests
- CESI C2005751 Switch-fuse combination making and breaking test / Earthing-switch 2 of SD short-circuit making tests
- Enel approved: GSM001 - GSCM004
- Service continuity: LSC2A
Patent pending
- IT0177-22-PA098570IT01-BOFFETTI S.p.A.-EA
- IT0925-20-PA084537IT01-BOFFETTI S.p.A.-EA
- IT0176-22-PA098569IT01-BOFFETTI S.p.A.-EA
Benefits
- Extremely compact: 330 mm module width up to 24 kV, 400 mm for 36 kV units
- Integrated system, switch plus three-position disconnector
- Integrated current and voltage sensors
- MV cable connectors with integrated current and voltage sensors
- Can be equipped with integrated systems (three-position switch-disconnector) or three-position switch
- Synoptic diagram to visually identify the position of the appliances
- Separate and interdependent operating mechanisms
- Application of fuses to DIN standards with striker
- Automatic device release for blown fuses
- Lockout in open circuit breaker or disconnector due to melting or lack of fuse
- AFL-AFLR accessibility.
- Safe accessibility of the line compartment thanks to the standard interlocks and the disconnector in earthing position
- Maintenance free
- Simplified and safe removal of fuses from the front of the cabinet
- Metallic segregation of the line compartment
- Voltage presence device (line side and / or load side) powered by integrated voltage sensors
- Equipment enclosures in stainless steel guaranteed “Sealed for life” and equipped with large relief valves
- Use of automatic production equipment and procedures
- Automated control and testing systems in each production phase
- Functionality test and inspection of components and units
- Long electrical and mechanical life
- Fully manufactured at Boffetti workshop